Limit circuit fault furnace

Gas and Oil Home Heating Furnaces - Goodman Furnace Open High Limit (code: 4 blinking lights) - Hello, I have a Goodman Furnace, model GDH80703AXAC, it was installed a little under a year ago. It worked fine for the first year and fine so far for this year. Until about 2 days ago. The burners went out, and when I

Limit circuit fault furnace. Lennox Furnace Reset Instructions. Step 1 —Switch off the power to your furnace and at the breaker. Usually your furnace is labeled at your breaker box. Step 2 —Locate and remove the control panel of your furnace. This will be located in different areas depending on the type of furnace you have; downflow models will have their control ...

Getting limit circuit fault on plus 80 furnace. 2010'ish. yes, flashing pattern indicates "Limit Circuit Fault". then - Answered by a verified HVAC Technician We use cookies to give you the best possible experience on our website.

PROBLEM: LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13.The circuit board sends signals that illuminate the diagnostic light with a number of flashes representing a particular code (similar to Morse code). ... This sail switch designed for rv and campers heater furnace fault use. $11.99. Buy on Amazon Price & availability info ... It's the job of the high-level/high-limit switch to shut down the ...CODE: 33. PROBLEM: LIMIT CIRCUIT FAULT - Indicates a limit, or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts of Flame rollout switch requires ...These fault codes (not always fault by the way) can help an HVAC tech repair the gas furnace more quickly than if he had to start at the beginning of the sequence of operation for the gas furnace. All manufacturers are different, especially the ignition control module or circuit board manufacturers. Not every OEM or furnace manufacturer makes ...Page 19: Status Code 4 - Limit Circuit Fault Status Code 4 LIMIT CIRCUIT FAULT - This status code indicates the limit, flame rollout switch is open, or the furnace is operating in maximum-heat only mode due to 2 successive limit trips while operating at any rate < 71% of maximum rate.My furnace is giving me an fault condition of limit circuit open or. Bryant furnace: bryant furnace limit switch locationHvac 4eaf b759 furnace Carrier comfort 92 furnace 33 limit circuit fault to 13 limit circuitLimit circuit fault, need second advice (carrier 58mvb).Thanks in advance. Fojo. HVACDave said: Hi Mudtruck, To determine if it is code 13 or 31. The first digit is the number of short flashes, the second digit is the number of long flashes. 13 is limit circuit lockout, in which case your furnace would try and restart after 3 hours. The limit circuit is there to protect the furnace from overheating ...Page 59 TROUBLESHOOTING Green Amber Symptoms Fault Description Check Cautions LED Code LED Code LED Code •Temperature rise, duct static, •Furnace does not •Four •Open limit circuit, main •Confirm electrically safe gas pressure, burner alignment, operate, four Red •None •None repeating limit, aux limit, or roll out condition before ...

Are you considering a Rheem furnace to replace your old, worn-out furnace? Here's what you can expect from Rheem with furnace costs. Expert Advice On Improving Your Home Videos Lat...When the draft inducer is working as it should, the pressure switch then completely closes the circuit (turns on). Issues. When there is an issue with the draft inducer motor, the pressure switch will then open or turn off. The furnace then shuts down to prevent ignition since there could be a buildup of those dangerous gases.Bryant furnace: limit circuit lockout bryant furnaceHave a carrier 48gs-030060301 package, the fault code is 1 flash=fan on Power line carrier channel (plcc) and application of transmission lineCarrier infinity thermal lockout.How to test and fix a faulty Goodman furnace limit switch. In most cases, a malfunctioned limit switch will have to be replaced. ... A blown fuse or tripped circuit breaker. An internal fault with the integrated control module. ... A Bad Solenoid Valve (Printed Circuit Board) During a furnace igniting process, 24 volts are sent to the gas valve ...Nordyne furnace #fg6ra072c-012a limit circuit open I have a frigidaire/Nordyne furnace... I have a frigidaire/Nordyne furnace model #fg6ra072c-012a and it has been blowing cold air since last night and the burners are not turning one.

83.6k 30 138 232. asked Dec 24, 2016 at 0:35. user64183. 3 1 1 3. If the blower is not running, the furnace will surely overheat. Get the blower running, and you shouldn't have a problem. - Tester101. Dec 24, 2016 at 15:49. Add a comment.Lets go to the furnace. Open top panel and give me model from label in burner section. Then let me know if you have a multi meter for testing voltage an troubleshooting. ... led flashing 33 limit circuit fault. HVAC Technician: ... The amber LED gives a status code of 13 [LIMIT CIRCUIT LOCKOUT]; I have tried turning the furnac ...A. The voltage of a furnace depends on the type of furnace. An electric furnace requires 240 volts of power, carrying 60 to 80 amps. A gas furnace only requires 115 volts at 5 to 10 amps. This means a gas furnace will typically use a regular wall outlet for power, while an electric furnace will require more electricity and a dedicated circuit ...Carrier furnace fault code 13 limit lockout . Carrier furnace fault code 13 limit lockout is one of the most common problems homeowners encounter. It can be frustrating and intimidating to troubleshoot the issue, but the good news is that it can be fixed with some simple steps.13,008. Post Likes. Originally Posted by The Gaffer. Have a customer with a ICP high efficiency furnace, throwing a 4 flashing light code, limit switch open. Here is what I have done so far (most as part of general service): Changed 2 x limit switch. Changed Pressure switch. Changed ignitor. Changed flame sensor.

Gregg giannotti twitter.

4 - LIMIT CIRCUIT FAULT: Indicates a limit or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #7. If open less than 3 minutes status code #4 continues to flash until blower shuts off.Furnace bryant lockout failed bl payne indicates blower owerI've got a open limit switch fault indicator light on my furnace Carrier comfort 92 furnace 33 limit circuit fault to 13 limit circuitMy furnace is not coming on. the power is working, and the led status. Check Details Limit circuit fault, need second advice (carrier 58mvb) If your gas furnace is not heating properly, the problem may be a faulty limit switch. In this video, we'll guide you through everything you need to know abo... Limit switches don't usually wear out by themselves. They are a safety device that is never actually intended to be used. So it should last the life of the furnace. Even if they do get a lot of use (if an air filter gets neglected and clogged), the airflow issue can be corrected and the defective limit switch can be replaced.I just had the exact same thing just this morning with a 12yr old Bryant that is identical to your Carrier. Showing code 33; limit fault. The limit switch was stuck open. Found a dirty filter, and almost half the supply registers closed. Pulled the blower and found 3 of 4 HX cells cracked.Solutions: Reconnected loose hoses. Remove debris; replace any cracked hose (s). If the hose ports - where the hoses attach to the switch - are cracked, replace the pressure switch. DIY Cost: $14 - $44 This is the price range for most gas furnace pressure switches. Average cost is about $25.

The circuit board is responsible for controlling the various components of the furnace, including the blower and the gas valve. If the circuit board is not functioning properly, it may prevent the furnace from igniting and producing heat. In this case, the circuit board may need to be replaced in order to fix the problem. Faulty Limit ControlFurnaces may have multiple limit switches. Limit switches are found on all types of furnaces, whether they run on oil, gas or electricity. The primary limit switch is a temperature-activated sensor that protects your furnace from overheating whenever the fan fails to blow enough air over the heat exchanger. The limit switch also controls when ...1. Code 33 - Limit Circuit Fault. This code often implies that the furnace has exceeded its safe temperature limit. Overheating can lead to other components' premature wear and tear, and it may even pose a fire risk. It's advisable to turn off your furnace and contact a professional as soon as possible. 2. Code 13 - Limit Circuit LockoutSo, you need to check the clamping system of the exhaust. Fan Speed Controller: The fan speed controller can be found at the top of the furnace. If it gets stuck, then you need to adjust it. Heat Exchanger: A clogged heat exchanger can cause problems in the heater. You need to check it properly.Bryant Furnace parts on amazon→ http://amzn.to/2wY6FDfThere are several troubleshoots the furnace sticker lists that might be the problem. I point out severa...Our Gibson has 1 light flashing and the code "limit circuit open or external load on w". The blower won't stop blowing. It was fixed for 1 night and gave heat after a new igniter ( no heat before).A properly chosen panel would not allow high fire if only one zone were calling. And a good panel would have a thermistor in the supply that shut off the furnace before the furnace's limit did. You let the furnace's limit open a few times and it will like to stick open leaving you cold. Reply. 10-23-2010, 12:22 PM #5.Candace Baker, Car Insurance WriterApr 7, 2023 No-fault insurance is a system of car insurance laws that requires drivers to use their own coverage to pay for basic medical expense...

Here are a few possible causes of tripped flame rollout switch: 1. Clogged exhaust vent. A clogged exhaust vent will restrict airflow through your heat exchanger. If airflow is restricted through the heat exchanger, then flame rollout can occur. Be sure to check your exhaust vent for any possible obstructions.

On the "first" call for heat, the high limit has cooled enough that the inducer comes on and the burner lights. When the high limit trips, the indoor fan and inducer continue to run until the limit cools, then lights the burner again. It continues this cycle until the thermostat is satisfied. I get 4 flashes on the board, High Limit, but the ...Jan 8, 2011 · My bryant gas heater is displaying a code 13 limit switch lockout and after 3 hours and the manual reset has been activated it comes on and works till the thermostat reads about 60-61 degrees and then shuts off. I've replaced the air filter and used some sandpaper to clean off the sensor rod that sits on the left side of the burner. Furnaces with a one-piece front cover — Remove the front cover first. The inspection port is usually on the secondary cover for the lower compartment. ... Limit circuit fault — high limit or rollout limit switch open. Blocked filter or secondary heat exchanger, or failed blower motor. Professional diagnosis required. 3 short and 4 long ...22 Aug 2018 ... Gas furnace not igniting - Goodman furnace wont ignite - DIY Gas furnace repair ... Furnace is in lockout mode! MR HVAC101•10K views · 6:03 · Go ...Bryant furnace code 33 (3 short flashes and 3 long flashes) indicate a limit circuit fault – this means that the high limit switch has been open. Such an error can appear if there’s a lack of airflow; …Bryant Furnace Limit Circuit Fault - 33 Thread starter GCC; Start date Jan 30, 2022; Users who are viewing this thread. Total: 1 (members: 0, guests: 1) Prev. 1; 2; First Prev 2 of 2 Go to page. Go. GCC Member. Messages 38 Reaction score 0 Points 6 Location Tampa, FL. Feb 6, 2022 #21The light indicator on the circuit board is lighting up 1 time every 3 seconds which on the fan motor they have provided a summary chart indicating "Air Flow / Limit Fault" but I can find no limitations to the air flow, it appears to fully flow and does occasionally work. ... i have a 2017 fe29 with the exact same furnace. if you look on ...Beginning January 1, 1992, all furnaces were manufactured with an integrated furnace control board, often referred to as FCB (Furnace Control Board). The FCB manages all operation requirements of the furnace. Fault and Information codes are displayed by one or more LEDs on the board. The FCBs used by York/JCI have the ability to store Read More...

Harmons grocery store brickyard.

Greer sc 10 day forecast.

* Update: I replaced the filter and that fixed the problem. Hope this helps and saves you some money.Here is short video showing how to read the blinking e...1 + 2. Blower is on after power up. Occurs if the unit is powered up during a call for heat or opens while the blower is on delay. 6 + 1. Ignition lockout. Control will auto-reset after 3 hours. LED is off. Secondary voltage fuse is open. Check whether the door switch isn't closed or for a short circuit.Furnace shut off with "Limit Switch Lockout" (code 13). Works for 24 hours after a reset, power cycle. ... and then furnace does function throughout the day. If I just power cycle (and don't press the reset switch) I get a limit circuit fault, code 33. ... had that happen on a 12-year-old Carrier that was throwing limit faults.the 33 is a limit, a limit would typically be any switch that break the 24volt circuit for the heat, could be the little discs the red wires attach to, by the inducer motor, the roll out switches, but if you can get the furnace to come back on without depressing any switches, it's probably the high limit, which means the unit if overheating.Received 2 Upvotes on 2 Posts. Welcome to the forums!! An open limit switch is indicative of an over temperature condition and is usually caused by a dirty/clogged air filter, a blocked/restricted vent pipe, an obstructed return air duct, or a dirty/clogged a/c evaporator coil (if equipped). The most common cause is an air filter that has not ...A 20-amp circuit is not limited by outlets, but by amps or watts used at once through the same circuit, and the circuit should not exceed 80 percent of its maximum load, according ...It's been cold here in Indy the last couple of days (6 degrees Fahrenheit) but the furnace will not get above 67/68. Runs for about 5 minutes then cycles to the blower for a few minutes. Shit appears to be working correctly. I removed the main limit switch earlier today to see if it was dirty and I heard an audible click.If the limit switch tests OK; or you've replaced it and still have the issue, you'll want to focus on the thermostat. From your description, it sounds more like a problem with the thermostat. Most safety mechanisms in furnaces do not let the furnace fire if there's a fault, so if you're getting flame I would not suspect a limit switch. I would ...Four red flash: 24-volt fuse or high-limit switch open. This code indicates that there is an electrical problem or an overheating issue. This can damage your furnace components or cause a fire hazard. Check and correct the size of your ducting system and make sure it matches your furnace capacity.Also, what exactly is a limit circuit fault? [4] LIMIT CIRCUIT FAILURE - Indicates whether the furnace's limit, a flame rollout switch, or high-heat only mode is being used due to two successive low-heat limit trips. The blower will run for about 4 minutes. or until open switch remakes are completed, whichever is longer. ….

The Open High Limit in a Goodman furnace shows the negligence that has been done, which has led to the furnace setting on the self mode. You can reset the Furnace by clearing the code and reconnecting the power. The primary role of a high limit is to protect the burner from getting over-heated that can cause damage to the whole burner.What causes an open limit switch on a furnace? If the air inside your furnace gets too hot, the limit switch trips to prevent overheating. If the furnace high limit switch trips due to overheating, there is likely an airflow issue that is preventing proper air movement through the system. Check your air filter, and replace it if dirty.CODE: Four LED flashes PROBLEM: Limit circuit fault: either a limit or flame rollout is open FIX: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower CODE: Five LED flashes PROBLEM: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized FIX: Check for a ...Are you considering a Rheem furnace to replace your old, worn-out furnace? Here's what you can expect from Rheem with furnace costs. Expert Advice On Improving Your Home Videos Lat...Advertisement Oil-fired burners are used in many parts of the country as the basic heat source for warm air and hot water heating systems. Most of the home oil systems in use today...What I found was there are 2 additional limit switches in series attached to either side of the blower fan. I (temporarily) jumpered these out and low-and-behold the heat came on. The blower fan is operational and there are no temperature issues in that (or any other) part of the furnace.Lack of airflow. Too many registers closed or blocked. Dirty blower assembly. Dirty evaporator coil. Not enough to return air. It could be a lot of different issues. Limit switches don’t usually wear out by themselves.Carrier furnace with 33-limit faults. We installed the Carrier 59MN7 furnace along with an a/c unit last summer. The a/c modulates the fan speed up and down as it cools, and we found that it was nice and quiet as it blew cooled air at the lowest fan speed. However, ever since we began running the furnace for the first season, we find that ...Ask a technician to inspect your circuit. They can also check the wiring for breaks, tears, and burn marks. ... If the furnace is flashing because high limit and roll-out switches have detected a temperature-related anomaly, replace the filter. ... If the carrier furnace gets stuck in high-fire mode, you have a fault. The blinking yellow light ...What I found was there are 2 additional limit switches in series attached to either side of the blower fan. I (temporarily) jumpered these out and low-and-behold the heat came on. The blower fan is operational and there are no temperature issues in that (or any other) part of the furnace. Limit circuit fault furnace, A properly chosen panel would not allow high fire if only one zone were calling. And a good panel would have a thermistor in the supply that shut off the furnace before the furnace's limit did. You let the furnace's limit open a few times and it will like to stick open leaving you cold. Reply. 10-23-2010, 12:22 PM #5., LIMIT CIRCUIT FAULT: Indicates a limit or flame rollout is open. 5: FLAME SENSED WITH GAS VALVE OFF: Inducer will continue to run until fault condition is cleared. 6: IGNITION PROVING FAULT: Failure to sense flame. 4 consecutive faults will cause a 6 + 1. 7: LIMIT CIRCUIT LOCKOUT: Limit circuit open for more than 3 minutes. Auto-Reset after 3 ..., Aug 8, 2023 · Four flashes: High limit switch open. This code suggests that the furnace is overheating. Causes could be a dirty or clogged air filter, improper duct size, a faulty blower motor, or restricted circulating airflow. Clean or replace the air filter, ensure the duct size matches your furnace’s capacity, and check for obstructions in the airflow. , The circuit board sends signals that illuminate the diagnostic light with a number of flashes representing a particular code (similar to Morse code). ... This sail switch designed for rv and campers heater furnace fault use. $11.99. Buy on Amazon Price & availability info ... It's the job of the high-level/high-limit switch to shut down the ..., Furnace Generated Fault Codes. When it comes to the furnace component of a Carrier Infinity system, fault codes can help identify and address problems promptly. These fault codes serve as valuable indicators of issues such as blower motor faults, limit circuit lockouts, or ignition lockouts. By familiarizing themselves with these codes, users ..., LIMIT CIRCUIT FAULT, need second advice (Carrier 58MVB) I did call a Carrier trained technician and after checking all my system, he changed the limit switch but I'm getting again the same problem. So before we try other things, like disassembling the furnace to access the heat chamber, which is going to be very expensive, I'd like to get more ..., 4 – LIMIT CIRCUIT FAULT: Indicates a limit or flame rollout is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If open longer than 3 minutes, code changes to lockout #7. If open less than 3 minutes status code #4 continues to flash until blower shuts off., The limit switch is located in the furnace cabinet on a special panel beneath the heating ducts. To access it, reach below the ducts and open the panel. You’ll find the limit switch on top of the panel. It’s a small plate the two metallic arms sticking out. The two arms regulate indoor temperature., Possible Causes for 4 flashes on a Goodman furnace. • Check filters andductwork for blockage.Clean filters or removeobstruction. circulator blower speed, orfailed circulator blower. • Check circulator blowerspeed and performance.Correct speed or replaceblower if necessary. • Misaligned burners, blockedflue and/or air inlet pipe, …, Remember, just like cars, furnaces have different models and types. Some use a hot surface ignitor, which heats up and glows bright to ignite the gas. Others might employ a spark ignition, which uses a high voltage spark to ignite the gas. The "furnace light blinking 4 times" fault code usually indicates a problem with these components., Furnace circuit cycles thermal trippingCarrier model 58sta070-12...flashing code 33,(limit circuit fault),,,,furnace ignites,blower Furnace basement electric switch pipes breaker gas unfinished making musty noise smell limit primary size hunker knocking story buzzing doesGot this new motor installed electric furnace. first co motor. can i ..., Carrier Fault Code 179 – Outdoor Unit Communication. First things first, make sure that you have power to the outdoor unit. If this part of the system is not receiving any power, then it will not register. Also, do check the outdoor circuit board – there shouldn’t be any blown fuses or tripped breakers., To read American Standard furnace codes, you need to check the color and the number of flashes of the LED display. Each color and number combination has a different meaning and indicates a different issue. Here is a summary of what each color and number means: Green flashes: Normal operation. One green flash: No call for heat., Instead, the Payne limit switch detects how many times a burner fails to turn on. The ignition cycle can run three times without the switch activating. After that, the limit switch will close off gas flow to the burner and force the system to enter a lockout mode, where units, including the air conditioner, will not function., Model number 58MTA080-F-12112. It is giving off code 33 which is limit circuit fault. The funny thing is that the house still heats up. I ran the furnace all winter last year like this. Very rarely do I get a lock out. Last night I got a 14 code ignition lock out. I reset the furnace and went to sleep., Jan 8, 2011 · My bryant gas heater is displaying a code 13 limit switch lockout and after 3 hours and the manual reset has been activated it comes on and works till the thermostat reads about 60-61 degrees and then shuts off. I've replaced the air filter and used some sandpaper to clean off the sensor rod that sits on the left side of the burner. , Furnace Gets power, fan turns on, no gas is burning and checked the gas lines for turned off valves. Please help! Thanks in advance for anything you can contribute, The circuit board indicated a no.1 fault (Air flow/Limit Fault). I dismantled the furnace blower (from the outside, without removing the furnace) and discovered that the problem was the sail switch was improperly placed, and rubbing against the outside housing (sticking, in other words). I fixed that, and all is good now., [4] LIMIT CIRCUIT FAULT - Indicates the limit or a flame rollout switch is open or the furnace is operating in high-heat only mode due to 2 successive low-heat limit trips. Blower will run for 4 min. or until open switch remakes whichever is longer. If open longer than 3 …, History of Electrical Circuits - The history of electrical circuits can be traced back to early investigations of static electricity. Learn more about the history of electrical cir..., Defrost Fault A: 3 Flash: 68: Defrost Fault B and/or C: N/A: 4 Flash: Defrost Fault A and [B and/or C] 5 Flash: 67: Ambient Temperature Sensor Fault (Out of Range - Open or Shorted) ERR 67: 6 Flash: Coil Temperature Sensor Fault (Out of Range - Open or Shorted) Low Pressure Cut Out Fault (Open outside of defrost Cycle-Hard lock out, cycle ..., In this episode of Repair and Replace, Vance shows how to replace the high limit switch in a gas furnace. The limit switch is a safety switch that monitors t..., Page 9 33 LIMIT CIRCUIT FAULT – Indicates the limit, or flame rollout is open or the furnace is operating in high-heat only mode due to 2 successive low or medium heat limit trips. Blower will run at medium heat airflow for 4 minutes or until open switch remakes whichever is longer., This video provides step-by-step instructions for replacing the limit switch on Payne furnaces. The most common reason for replacing the limit switch is the ..., CODE: 6 + 1. PROBLEM: Ignition lockout. FIX: Control will auto-reset after 3 hours. CODE: LED is off. PROBLEM: Secondary voltage fuse is open. FIX: Check whether the door switch isn't closed or for a short circuit. CODE: LED is on. PROBLEM: Control circuitry lockout. FIX: Will auto-reset after 1 hour., Sep 30, 2023 · How To Reset Furnace Limit Switch - Troubleshooting The Limit Switch On. Check Details. Ducane furnace model no. MPGA075B3B led fault code flashes 4 times high. Check Details. Fault Codes For Mid And High Efficiency Furnaces - YouTube. Check Details. My furnace was attempting to cycle and I read to clean the flame sensor. Check Details. Carrier ... , Plus I can repair anything myself as well and have all the tools, so no need for a tech and the cost of one. Here are my specs: Infinity Carrier. Furnace: 58MVC080-F-10114. software version: CEDR131312-13. SYSTXCCITC01-B. software version: 131626-03.60. Lennox PureAir model: PCO14-23. Thanks in advance!, The yellow light indicates the burner flame mode, while the green light indicates the fan mode. The codes can help you troubleshoot and fix some common problems with your furnace, such as a defective gas valve solenoid or an open circuit. Carrier furnace light codes are also in different colors of fluorescent tubes to help identify the system ..., fault condition limit circuit open pressure switch stuck open pressure switch stuck closed ignition failure 120vac and neutral reversed or no ground false flame or gas valve relay shorted off status light on 1 flash 2 flashes 3 flashes 4 flashes 5 flashes 6 flashes off . title:, Step 3: Check Your Furnace. If your thermostat and air filter are fine, but your furnace is still not working properly, you may need to check your furnace for other issues. Some common problems that can cause a solid yellow light on your Bryant furnace are: A faulty flame sensor: The flame sensor is a safety device that detects if there is a ..., CODE: YELLOW LED3 ON. PROBLEM: Furnace is operating in high heat. CODE: GREEN LED4 ON. PROBLEM: Furnace is operating in low heat. CODE: RED LED2 FLASHING. PROBLEM: Line voltage polarity is reversed. CODE: 11. PROBLEM: NO FAULT IN RECENT HISTORY DISPLAY- Indicates no faults have occurred within the last five cycles., Page 9 33 LIMIT CIRCUIT FAULT – Indicates the limit, or flame rollout is open or the furnace is operating in high-heat only mode due to 2 successive low or medium heat limit trips. Blower will run at medium heat airflow for 4 minutes or until open switch remakes whichever is longer., Limit circuit fault: either a limit or flame rollout is open: Check for: restricted vent; loose blower wheel; excessive wind; dirty air filter; or defective blower: Five LED flashes: An abnormal flame proving signal, the flame is likely proved while the gas valve is de-energized: Check for a leaky gas valve or a gas valve that is stuck open ...