Low subcool high superheat. Subcooling Is The Missing Piece Of The Puzzle. August 14, 2002. In past articles I've written about superheat as a charging and diagnostic tool. There are actually four pieces to the refrigerant system diagnostic puzzle: 1. Suction pressure; 2. High-side pressure; 3.

Low subcooling for R22. Low subcooling usually means your system is undercharged or has a dirty evaporator coil. It's like running your car with low tire pressure - it won't perform well. The solution? Add refrigerant or clean the coil, depending on the issue. High subcooling for R22. High subcooling often indicates overcharging or a ...

For superheat measurement, we use the blue low side gauge. The red one (high side) is for measuring subcooling on the liquid line. Needless to say, we: Don't want a very low superheat (0°F, 1°, or 2°F) since this indicates liquid refrigerant might be entering the compressor. The compressor can only handle vapor, not liquid.on target subcool with high superheat could mean a few things. 1. charge is low and condenser is underperforming 2. evap/condenser performing normally, but low charge takes txv out of range 3. low charge with restricted metering device. Reply . 06-07-2020, 11:28 PM #18. Adlerberts-Protege.Accurately Measuring Superheat And Subcooling. For example.....Let's say the low pressure curve on a system at an outdoor temperature of 85 degrees dry bulb, indoor wet bulb temperature of 59 degrees shows the suction pressure should be 71 pounds. The saturation temperature (this is an R-22 systems) = 41.7 degrees.May 25, 2013 ... Comments265 ; Why and How to Adjust a TXV / TEV. HVAC School · 413K views ; Superheat and Subcooling Explained! How to Easily Understand! AC ...If it does it in decent weather: It's airflow. Or, more accurately a lack of heat load on the evap. Your txv has bogged all the way down, creating a high subcool. It's bogged so far down, and still can't maintain a decent superheat. This is from your low evap temp, low sh and high subcool.

The system below is a walking freezer with a TEV. Refrigerant is R404a. Standard conditions are -10 °F box temperature for freezing (low temperature); 10 °F evaporator TD; 25 °F condenser split; 10 °F superheat; and 10 °F subcooling. From the information given on the diagram, answer the question below.On a txv system for comfort cooling superheat is commonly in the 10-15 deg. F range. anything outside of that range would be considered low or high. It of course is dependent on the valve superheat setting. This is all assuming that the system is running properly, there is not too much load on the evap, not too much load on the condenser and ...Check your wetbulb return air temperature - can use it to determine target supply temperature. 15F drop may be okay if it's relatively humid or the blower speed is set high. On a 3 ton drive furnace the fan should be on high or medium high for 2.5 tons, depends on your air ducts. On a 4 ton drive - lower.A low suction superheat does not 'indicate' an overcharge. Low suction superheat is the result of too much refrigerant in the evaporator for the heating loading of the evaporator at that moment in time. Post the startup report data: Outdoor Ambient temperature. Condenser air temp in. Condenser air temp out.High superheat low subcooling on a TXV system means that there is no sufficient amount of refrigerant in the evaporator and there is low amount of the refrigerant in the condenser unit. This condition is mainly caused by low charge in an air conditioning system and can be fixed by sealing leaks and adequately charging the system with a …Low superheat. Meaning? High subcooling meaning? Low subcooling meaning? Reply . 05-13-2015, 08:13 PM #2. Scott Kline. View Profile View Forum Posts View Forum Threads Professional Member Join Date Jan 2014 Location Pennsyltucky Posts 1,643 Post Likes Likes (Given) 1143162. 25. I know that having both high superheat and low subcooling on an Air-Conditioner (A/C) is a strong indication that an air-conditioner does not have enough refrigerant. When the charge on an A/C is low, there is less refrigerant that enters the evaporator. When there is a lower amount of refrigerant entering the evaporator, it takes …

Yes, high superheat and low subcooling can harm your HVAC system. High superheat levels can cause the air conditioning system to deliver less cooling. It can also cause the compressor to overheat ...Low subcooling means that a condenser is empty. High subcooling means that a condenser is full. Overfilling a system increases pressure due to the liquid filling of a condenser that shows up as high subcooling. To move the refrigerant from the condenser to the liquid line, it must be pushed down the liquid line to a metering device.Master the art of HVAC maintenance with our focused guide on troubleshooting subcooling and superheat issues. Learn to interpret the signs, pinpoint problems, and apply practical solutions for optimal system performance. With clear explanations and actionable advice, this guide is essential for any HVAC professional or enthusiast.Hey guys, could use some help. Had a Carrier unit with 410a, not sure of the metering device. Cooler weather, 63 outside, maybe 70 in the house, so obviously not a lot of load. I'd been seeing 20ish degrees of superheat all day on other calls. On this unit Suction was about 105\32, head was bouncing between 200 and 220. Subcool was bouncing between 10 and 15.This thread is in reference to residential split a/c units. I know with a TXV the charge should be checked and/or adjusted according to subcool. If working properly the TXV should pretty much hold the superheat at a constant. But I have seen superheat readings that to me look like the evap coil is being starved. For instance a SH reading …Yes, high superheat and low subcooling can harm your HVAC system. High superheat levels can cause the air conditioning system to deliver less cooling. It can also cause the compressor to overheat, potentially damaging it. The same goes for low subcooling.

In what episode did linda reagan die.

Currently: 30psig suction/55 superheat (47 if I check at evap) 330 psig head/50 subcool, sight glass clear. Outdoor ambient: 62. Freezer temp: 34 (working its way down) TD 5 degrees. I do have a significant layer of frost on the 3 dist tubes coming off of TXV.Normal to high subcooling + high superheat = possible restriction or bad txv - only if your temp readings are accurate. I doubt they are. Use real thermometers, no temperature gun. ... LOW CHARGE = High superheat. Low suction pressure, indoor TD, subcooling, head pressure & compressor current draw. OVER CHARGE = Low superheat. Normal indoor TD.Subcooling is when the liquid refrigerant in your is colder than the minimum temperature required to keep it from boiling. This can happen when the system is first turned on, or if there's a problem with the system. When this happens, the liquid refrigerant can change from a liquid to a gas phase, which can cause problems with the HVAC system.In this podcast episode, we ONCE AGAIN talk about superheat and subcooling. This episode is a recap to help people who struggle with the concept. You get superheat when you have 100% vapor, and you have subcooling when you have 100% liquid; any liquid-vapor mixtures are in a saturated state. We usually measure superheat outside at the suction ...Tripping High Pressure Switch. High Liquid Pressure/ Low Subcooling. Unit Running in Cool Mode. High Liquid Pressure / High Subcooling. Compressor Runs but Does Not Pump. High Suction Pressure / Low Liquid Pressure. Compressor Tries to Start But Does Not. Low Suction/ Low Superheat (fixed metering device)Today’s technology is about the future of application development rather than the past. The shift to modern tools such as low-code is happening no matter the controversies. Receive...

162. 25. I know that having both high superheat and low subcooling on an Air-Conditioner (A/C) is a strong indication that an air-conditioner does not have enough refrigerant. When the charge on an A/C is low, there is less refrigerant that enters the evaporator. When there is a lower amount of refrigerant entering the evaporator, it takes less ...Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in...What does low subcooling mean and how does it affect your refrigeration system? Learn about the causes and how to address this common issue…. Subcooling Low: Your …Refrigerant restrictions will be low suction: high superheat, high subcooling. Often once you resolve the charge issue, you may also find another low load issue that contributed to the freezing. In many cases, when a low charge is the main cause, the customer will notice the issue before the system is FROZEN SOLID.Well, now it has very low suction pressure plus suction-line icing-up; entirely different symptoms: Simple, when checking for restrictions: Refrigerant System RESTRICTIONS, either TXV or FIXED ORIFICE; low suction & head pres.; high superheat & subcooling; low amp draw; icing & poor Relative Humidity Control.System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.System Information R22 2.5 ton: Low Side: 115. High Side: 240. Return Air: 83. Suction Line Temp: 75. Measured Super heat: 5. Super heat should be around 15. Low superheat is an indication that liquid refrigerant not changing state in the evaporator and is possibly flooding back to the compressor.What does low subcooling mean and how does it affect your refrigeration system? Learn about the causes and how to address this common issue…. Subcooling Low: Your …R134a Low Subcooling, High Superheat. This is regarding the refrigeration system for a water cooler. The evaporator is immersed in the water to be cooled. The following information is available at 25 mins after starting the compressor: When water temperature was 7.8 deg. C. Evaporator Inlet: 0.7 deg. C. Suction: 23 deg. C. Discharge: 72.6 deg. C.A solid understanding of superheat and subcooling is essential. Troubleshooting often requires simultaneous knowledge of temperature, pressure, voltage, and current values in a system. A single-function meter won't permit a complete analysis of the system. Frequently, multiple tools are required. This article provides information on ...

To sum it up, high superheat and low subcooling are the two conditions that can greatly affect a system’s efficiency. They can happen when there is an undercharge of refrigerant. To fix them high superheat and low subcooling, you should check the refrigerant flow, airflow, metering device, condenser coil, and refrigerant coil.

An HVAC system is said to be running with high superheat or low subcool when there is a limited amount of refrigerant in both the evaporator coils and in the compressor. The possible reason for the high superheat and low subcool could be due. 1. Restriction in the liquid line. 2. Faulty metering system. 3. Excessive airflow through the ...Common Causes of High or Low Superheat. Superheat is a crucial factor in refrigeration systems that controls the temperature and pressure of refrigerants. It measures the amount of heat added to vapor from its boiling point at a particular pressure, indicating how well the evaporator coil transfers heat between refrigerant and air.Hey guys, could use some help. Had a Carrier unit with 410a, not sure of the metering device. Cooler weather, 63 outside, maybe 70 in the house, so obviously not a lot of load. I'd been seeing 20ish degrees of superheat all day on other calls. On this unit Suction was about 105\32, head was bouncing between 200 and 220. Subcool was bouncing between 10 and 15.Let's take a look at other possible causes. Low suction pressure problems can be divided into two subcategories — low suction/high superheat and low suction/low superheat: Low suction/high superheat: Moisture, dirt, or wax buildup in critical areas, especially the metering device. In Figure 6, this fixed metering device is 30% blocked.Low pressure 62psi @ 65 degrees superheat=30 degrees. With the above temps & 50% RH, the IWB depression should be close to 13 degrees, or RA 69-IWB with a SH target of approx 18 or 19-SH, not 30. Ultra High SC & High SH indicate restriction, probably at metering device or back toward condenser. That’s because low charge results in high superheat AND low subcooling (we have covered this in high superheat low subcooling issues here). We are left with only 2-3 culprits that can actually cause both high superheat and normal subcooling. These are: Too high indoor CFMs. Too high indoor load. Faulty measurement. Let’s look at all these 3 ... If superheat is low and sub-cooling is high: Charge must be adjusted. System overcharged If superheat is high and sub-cooling is high: Could have blockage in coil, orifice or line set. If superheat is low and sub-cooling is low: Orifice could be too big, there is no orifice in the unit of the orifice is stuck and refrigerant is by-passing it. Jess Gordon is the service manager at Tempo Mechanical Services, Irving, TX. The company was Contracting Business magazine’s 2003 Residential Contractor of the Year. Jess can be reached at 972-579-2000, or by e-mail at [email protected]. Superheat is a way to ensure that the system is boiling off all of the liquid before it exits the evaporator.I had posted in a previous thread about the superheat reading taken on my system being about 11 *F too low (possible overcharge). Today another tech came out and measured everything again. This tech measured the subcooling as well this time. Here are the measurements he took: OAT DB: 68 *F Low side: 68 psi (39 *F) High side: 140 psi …The symptoms are low suction, normal subcooling, and high superheat when a TXV fails “shut,” but there are some other issues to watch for that can actually result in overfeeding the coil. Schrader in the Port. The external equalizer tube on a TXV connects to the suction line at the evaporator outlet and provides a closing force to the valve.

Domino's pizza east stroudsburg.

Joann fabric pensacola fl.

Bryan with HVAC School goes over AC pressures, subcooling, and superheat in his troubleshooting mindset presentation from the BTrained HVAC training event in Birmingham, AL. Bryan also talks a bit about his educational photo-sharing app, MechPic. The suction pressure and suction saturation give us an idea of the refrigerant’s …If it does it in decent weather: It's airflow. Or, more accurately a lack of heat load on the evap. Your txv has bogged all the way down, creating a high subcool. It's bogged so far down, and still can't maintain a decent superheat. This is from your low evap temp, low sh and high subcool.May 6, 2015 ... Comments28 · Explaining Superheat and Subcooling to Your Apprentice! · Class - What Superheat Signifies · Super Heat : Total System Superheat &...The first benefit is the ability to maintain the minimum stable superheat within the evaporator. Here's a quick break down. When an evaporator is "under-filled" with refrigerant, the superheat signal is high and very stable at the outlet of the evaporator. Only a small area of the evaporator is utilized, resulting in degraded performance.In this HVAC Training Video, I Explain Why we need to Measure the Refrigerant Charge with Subcooling when a TXV Metering Device is used. I Explain why the To...One of the leading theories about depression is that it’s caused by low levels of serotonin. But the connection has not been proven. There’s a long-debated theory that low serotoni...Normal Subcooling High Superheat Scenario Causes of High Superheat with Normal Subcooling Low Refrigerant Charge. Picture your HVAC system as a marathon runner. Just as runners need proper hydration, your system needs the right amount of refrigerant. A low refrigerant charge can cause high superheat, making your system work harder and less ...For more tips, visit our website, http://www.edgetekhvac.com.To download a copy of our job sheet, visit our online literature library at: http://literature.n...Total Superheat with R22 = Corresponding temperature at suction pressure - Temperature measured at a suction line or outlet of the evaporator. The superheat is nearby 10 ° F in most cases. If the superheat is high, then it causes an increase in the heat of compression. This increase in temperature can affect the performance of the compressor.Low-code is a way to design and develop applications with little or no coding. It empowers users with little to no technical background. * Required Field Your Name: * Your E-Mail: ... ….

Let's start with subcooling. This process helps improve your refrigeration system's efficiency by increasing the capacity of the refrigerant and reducing the formation of flash gas. In other words, subcooling helps your cooling system work harder and better. It's like giving your fridge a superpower!If you’re on a potassium-restricted diet, it’s important to stick with foods that are going to help you stay on track and feel your best. Learn more about some common foods that ar...Ok so my question is this, I just recently moved to another company, they tell me to do sh and sc by just hooking gauges and add or subtract line temp from what gauges reading. And use 10 degree for sc and 20 for sh. shouldnt I be taking indoor wet bulb and outdoor dry bulb.Troubleshooting Using Superheat and Subcooling Data. Low superheat: Indicates too much refrigerant in the evaporator, likely due to overcharging. High superheat: Suggests too little refrigerant in the evaporator, which may be caused by low refrigerant levels, insufficient heat reaching the evaporator, or a dirty/defective metering device.A low condenser subcooling can mean a low charge. A high condenser subcooling can mean an overcharge, but not always. Capillary tube systems: This is not true for capillary tube systems because the majority of them have no receiver. A capillary tube system can run high subcooling simply from a restriction in the capillary tube or liquid line.Watch on. You can find your target superheat using charts, such as manufacturer-provided ones or universal ones from sources like TruTech Tools or the HVAC School app. You need the outdoor dry-bulb temperature and the indoor wet-bulb temperature; the indoor wet-bulb temperature gives you a better idea of the total indoor load on the coil.Superheat is calculated as the difference between the saturation temperature of a substance and the actual temperature of the gas. 3 When it comes to HVAC, refrigerants often boil at much lower temperatures than water. For example, if a liquid refrigerant boils at -10 degrees and is then heated up to -5 degrees, it has been superheated by 5 ...More subcooling is better but we have to consider the benefit vs. cost. It doesn't make sense to make a large investment in equipment, service and maintenance for a small gain in subcooling and efficiency. 3. Low superheat is caused by more refrigerant being delivered to an evaporator than can be evaporated by it. High superheat is the …Apr 18, 2017 ... In this HVAC Refrigerant Charging Video I go over what it means to have low R-22 Freon or Low R-410A Suction Vapor Pressure along with a Low ...A superheat reading indicates that there is liquid refrigerant at the location. No, superheat indicates vapor refrigerant. What is subcooling. Liquid refrigerant cooled below its saturation temperature. Name two places in a refrigeration system that subcooled liquid can be found? At the condenser outlet and the liquid line. Low subcool high superheat, A high superheat is an indication of either a low refrigerant charge or a liquid line restriction problem. To tell the difference between the two problems, we look at subcooling. A system with a low refrigerant charge will have a low subcooling. A system with a liquid line restriction will have a normal to high subcooling., Hello I have a 20 TON AAON Split coil condenser, each compressor is 10 tons. Unit is R410A. Semi annuals have just been done on the unit so all coils and filters are clean. Outdoor air was 93, indoor was 67. Condenser has 2 fans and both are running at proper speed. The high superheat and low subcooling would normally suggest to me that the unit is low on Freon and needs to be charged, but my ..., High compressor superheats: Because the liquid line, TXV, and evaporator are being starved of refrigerant from the undercharge, the compressor will be starved too. This can be seen in the high compressor superheat reading. Low condenser subcooling: In TXV systems, the compressor is seeing much warmer vapors from the high superheat readings. The gases entering the compressor will be very ..., Evaporator Superheat Method: 1. Take the suction line pressure and temperature at the condenser's suction service valve (air conditioning) or service port at the compressor (heat pump). If you use a probe-type thermometer, put a piece of pipe insulation around the probe and pipe. 2. , If it does it in decent weather: It's airflow. Or, more accurately a lack of heat load on the evap. Your txv has bogged all the way down, creating a high subcool. It's bogged so far down, and still can't maintain a decent superheat. This is from your low evap temp, low sh and high subcool., High superheat due to excessive heat load and low subcooling due to poor compression. In practice, more than 95% of issues, when we see high superheat and low subcooling, …, However, the undercharged system will have low subcooling levels. Technicians often confuse an undercharged system with a restricted metering device. ... This will cause the compressor superheat to be high. The 100 percent saturated vapor point in the evaporator will climb up the evaporator coil, causing high superheats. Low Amp Draw, the superheat constant. Subcooling involves two measurements as well: one for pressure and one for temperature, but this one is taken from the liquid line. Target subcooling can be found on the system nameplate. The actual subcooling should be within ±3°F of the target subcooling for correct refrigerant charge. An improper …, Attach the Manifold Gauges. Connect the manifold gauges to the low-pressure port. Ensure it is attached securely to prevent any leakages and to get accurate readings. Take Temperature and Pressure Readings. Using a thermometer, take the temperature reading of the suction line — this is the line that carries the refrigerant back to the unit., Refrigerant restrictions will be low suction, high superheat, high subcooling. Often once you resolve the charge issue, you may also find another low load issue as well that contributed to the freezing. In many cases when low charge is the cause, the customer will notice the issue before the system is frozen solid. ..., Subcooling is a measurement of temperature DECREASE of a liquid below its saturation (mixed liquid/vapor) temperature at a given pressure. For example, water boils at 212° Fahrenheit at sea level (atmospheric pressure of 14.7 PSIA). If water is 212°F and at atmospheric pressure at sea level, you can be sure it is at saturation, which means it ..., I had posted in a previous thread about the superheat reading taken on my system being about 11 *F too low (possible overcharge). Today another tech came out and measured everything again. This tech measured the subcooling as well this time. Here are the measurements he took: OAT DB: 68 *F Low side: 68 psi (39 *F) High side: 140 psi (78 *F) High side line temp: 71.7 *F Subcooling: 7 *F ..., Let's start with subcooling. This process helps improve your refrigeration system's efficiency by increasing the capacity of the refrigerant and reducing the formation of flash gas. In other words, subcooling helps your cooling system work harder and better. It's like giving your fridge a superpower!, Compressor amperes: low. Low side pressure: 11.6 psig/10° High side pressure: 95.0 psig/85° Ambient temp: 80° Calculated Values. Condenser split: 5° Condenser subcooling: 10° Evaporator superheat: 15° Superheat at compressor (total): 45°, The higher the efficiency of a system, the more critical it is that it is charged properly. The Fieldpiece Superheat and Subcooling for Air Conditioning and Refrigeration meter, model SSX34, measures suction line, or low side, line temperature and pressure. It then calculates actual superheat in real time using built in P/T charts., Superheat Good Subcool Good High SH Low SC ... High Low Low Low High Over-Charge High High Restricted Low Low Over-feeding Only evaluate charge after the airflow has been confirmed to be accurate and coils are confirmed to be clean. College of HVAC Education . Title: Microsoft Word - Thumb Chart complete.doc ..., Hey my fellow tech. I recieved a call today that the unit was freezing over on a old carrier unit. So i went through the protocol, IDM, Filter, Evap coil, ductwork, all checked out good. Before i continue recommend every tech to go get the testo 550 they're so nice. Anyhow hooked up my testo to the unit the unit and checked my superheat sence it had cap tubes., For superheat measurement, we use the blue low side gauge. The red one (high side) is for measuring subcooling on the liquid line. Needless to say, we: Don’t want a very low superheat (0°F, 1°, or 2°F) since this indicates liquid refrigerant might be entering the compressor. The compressor can only handle vapor, not liquid., Sep 6, 2018 · I come back the next day expecting to have to pull charge out and the subcool being way high. The unit cooled the house down to 70 it’s probably 85 outside. These are my readings 296psi high side, 95.8 lstat, 93.6 line temp, 2.3 subcool. 140.6psi low side, 50.1 vstat, 51.3 line temp, 1.2 superheat. 20degree delta tee across the return and supply. , High superheat refers to a value of superheat that's higher than recommended. As an example: If a system with a target superheat of 10deg is running a 28deg superheat, it has a high superheat. Superheat is the difference between the suction line temperature and the suction saturation temperature, so it's a subtraction of those two numbers. IE: , Superheat is checked by measuring the temperature of the vapor line, measuring the pressure, then subtracting the saturated temperature from the measured temperature. In the case of a blend, you Simply read the saturated temperature next to the pressure in the vapor (dew point) column of the chart. When checking the subcool condition the ..., In this HVAC Video, we go over the Superheat and Subcooling Process during the Refrigeration Cycle on a Heat Pump. Understanding these concepts is very impor..., 1 post · Joined 2023. #4 · Mar 5, 2023. High superheat with a normal subcooling occurs in a refrigeration or air conditioning system when the refrigerant vapor leaving the evaporator is heated to a temperature above its saturation temperature at the given pressure. The causes of high superheat can include:, At approximately 85 degrees Fahrenheit (29.4°C), the pressure for R-410A could be around 230-260 psi on the low side and 500-550 psi on the high side, but actual values can vary. What happens if superheat is too high? Excessive superheat can lead to reduced cooling capacity, insufficient cooling, and potential compressor issues., A total superheat of 0°F to 5°F, a saturated temperature above 36°F, and a Delta T of 20°F to 24°F is a very good indication that the system is charged properly. However, this does not mean that we should charge a system that is low on refrigerant to these numbers., Superheat that is too low or too high may cause damage to a compressor. A refrigerant with a 0°F superheat value (saturated refrigerant) at this location indicates that some amount of liquid refrigerant is returning to the compressor. In this condition, the amount of liquid refrigerant returning is unknown, but any amount is too much. ..., That’s because low charge results in high superheat AND low subcooling (we have covered this in high superheat low subcooling issues here). We are left with only 2-3 culprits that can actually cause both high superheat and normal subcooling. These are: Too high indoor CFMs. Too high indoor load. Faulty measurement. Let’s look at all these 3 ... , Low superheat low subcooling. Orifice-related problems. High superheat high subcooling. Usually caused by a blockage in the line, coils, or in the orifice. High subcooling normal superheat. Might be caused by a flooded condenser. High subcooling low superheat. This might be a case of a high refrigerant charge. Action: Remove refrigerant., Conversely, if the valve is stuck open, it can lead to low subcooling. Incorrect Refrigerant Type: Using the wrong type of refrigerant can disrupt the system's performance, causing superheat and subcooling issues. Fixing Low Superheat and Low Subcooling. Check Refrigerant Charge: Start by checking the refrigerant charge using a manifold gauge ..., ant type used. The difference in temperature is the subcooling value. Note: Condensing temperature is derived from using the PT chart. On new refrigerant blends with high temperature glide, this is called the bubble point (BP) temperature. See Figure 2. To measure subcooling with an 80PK-8 Pipe Clamp, allow the system to run long enough for, May 15, 2021 · 3. Airflow through the evaporator is too high. When there is an excess flow of air through the evaporator coil, the capability of the system to remove moisture is reduced. The vapor picks up more than usual heat which causes the suction pressure to be higher than normal pressure and has a higher superheat. 4. , In extreme cases, insufficient subcooling can even cause the refrigerant to return to a gaseous form before reaching the evaporator piping. The most common cause of insufficient subcooling is low refrigerant charge. However, too much subcooling can damage your system. An excessive amount of coolant will raise subcooling to a problematic level., The result is low superheat. Here is how we fix low superheat due to overcharged AC unit: We have to remove the refrigerant (R-22, R-410A, R-134A, etc.). This is simple to say but hard to do. We have to leak the AC unit, and that job is best left to licensed HVAC technicians (with a license to drain freon). This is not a DIY low superheat fix.