Running pressures for 410a

1) R22 and R410A Compressor #1 2) R22 and both R410A Co mpressors 3) Only R22 4) Only R410A Compressor #2 EXPERIMENTAL RESULTS R22 System Tests Figure 3 shows the cooling capacity and COP as a function of the outdoor temperature. Capacity ranged from 11.78 kW (40201 Btu/h) to 8.71 kW (29711 Btu/h) over the range of outdoor temperatures.

Running pressures for 410a. Both refrigerants, R22 and r410a work off of pressures. Mor specifically they work off of a balanced ratio of vapor and liquid pressures. ... Moreover, the operating, running pressures are closer to 165 PSI at the coil. Contamination. Based on a 9 year history of this practice and 2 dozen plus warehouse test mutts, we know conclusively that ...

TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 …

When charging a refrigeration system, there are five main rules to follow: Rule 1. Always charge a receiver/sight glass/TXV system under a high evaporator heat load. This could mean simply opening the doors or putting an artificial or false heat load on the evaporator. Rule 2.During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on the wet bulb temperature inside the building and the ambient temperature outside the building.Not a dry charge he said he reclaimed the 410a and ran a vac on it, then installed 407c into the unit. I asked a lot of questions because I have never heard of such. The unit is a complete brand new unit 80% up flow,60,000 btu, 13 seer, 2.5 ton all matching goodman equipment. Reply. 05-14-2013, 12:38 PM #7.They recorded a 245 psi Head pressure and 115 suction pressure on my installation receipt. He also wrote "10 degrees subcool" on the receipt, which I don't see how that is possible when a 245 psi equals 83 degrees on an R-410a P/T chart. The small, copper liquid line (when measured near the compressor valve) doesn't seem to heat up …Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures. On a properly-charged and working air conditioning system using R-22 refrigerant. Low pressure refrigerant switches on Carrier HVACR typically open at 50 psi and close at 100 psi.What is r410a’s suction pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Related Articles:I originally wrote this guideline back in 2003, and truthfully, not much has changed since then in regards to checking a heat mode charge on a heat pump. Step #1 - If there is any frost on the outside unit, get it completely defrosted first. Step #2 - Check all the obvious things first, filter, coils, blower wheel, etc.R-410A air conditioner and heat pump split system matches of nominal capacity 90,000 and 120,000 Btuh. This guideline ... Proper adjustment means pressure and temperature of the liquid line at the indoor unit must be measured to calculate subcooling at the indoor unit. If subcooling at the

1-3. Refrigerant Flow Diagram Outdoor Units: U-60PE1R5 / U-71PE1R5 Indoor Unit: Accumulator Compressor Gas line service valve High pressure ø15.88 switch Muffl er Heat exchanger 4-way valve Heat exchanger Distributor Freeze-prevention coil (Attached to the heat exchanger) Electronic ref. Strainer control valve Liquid line service valve...One such substitute that has gained widespread acceptance is R410A, a hydrofluorocarbon (HFC) blend. Unlike R22, R410A does not contribute to ozone depletion and has a lower GWP. This makes it an attractive choice for manufacturers who want to comply with environmental regulations while maintaining the efficiency and performance of HVAC systems.Refrigeration Product Bulletin R-448A APPLICATIONS: • Low Temperature Refrigeration • Medium Temperature Refrigeration PERFORMANCE: In R-22 Applications • Higher System Pressures • Lower Discharge Temperature • Existing TXV is suitable (some adjustment will be required) • Change lubricant to POE per manufacturer's instructions In R-404A (or similar) ApplicationsRefrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ... common refrigeration expertise in determining the correct operating pressures, based on the actual conditions. Ind. Title: Temperature-Pressure Chart.xlsxIt may run better on 410a, depending on the compressor type. Compression ratio on 410 will be lower, which will help a recip. Keeping the motor cool and lubricated is key, as usual. If it's got POE in it already, then I'd try it. If it's mineral, maybe drop some Supco88 into it first.21 Sept 2017 ... 410a refrigerant is approximately 32 degrees at 100psi. Typically a 410a low pressure switch will open at 50 psi. If you need further help, ...

Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 15718 Sept 2020 ... When your compressor has both a low head pressure and a high suction pressure your refrigeration equipment is still running, but the temperature ...The standing pressures on a 410a system will be between 200-240pso usually. This is going to vary a little based on ambient temp and the amount of refrigerant in the system. This is with the system off, for clarification. ... I have a GE frige that was running all the time and not staying cool. I took the back of the freezer off and saw that ...indoor return temp 70. outdoor temp 70. discharge temp 83. pressure readings 279 / 120.5. suction line temp 56.7. liquid line temp 71.7. superheat 30.8. subcooling 33.9. since I havent worked with many R410A units with TXV's, I'm feeling I've got a bad TXV valve.The perfect refrigerant reading depends on several factors, like atmospheric pressure and temperature. I like to see an average range of 58-85 PSI on the low side and 120-300 PSI on the high side. These indicate that the unit is running okay and should be cooling properly. TL;DR: R22 is almost phased out and even banned.

Loca luna restaurant.

R410a freon replacement costs around $260, on average, and most homeowners pay between $140 and $380, depending on the quantity and location. R -410A refrigerant costs anywhere from about $140 to $380 per 25-pound container. Costs rise in the summer when the demand for indoor cooling surges. To replace R-410A refrigerant, you can expect to pay ...With 75 indoor you should be running approximately 190 on the low side. The correct way to charge the unit would have been to weigh the charge in and in the cooling mode. So if you have 190 suction I would leave it as is and return when it is warm (70) outside to adjust the charge. Bart Jay. 655 Satisfied Customers.Gas charging ,R410A R22 R32 pressures, - HINDI This video is helping to know identify the gas in the air condition unit and what kinds of the pressure we will maintain to the ai... Refrigerant pressure readings R-22, R-410A, R-290, R-417AC22.2 Intertek N0. 236 3097844 MS-SVU40A-EN Literature Order Number Date June 2012 April 2010 Supersedes The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. @ 2012 Trane. View and Download Daikin R-410a owner's manua online. 60hz. r-410a air ...Fan pressure sw ., cut out / cut in, PSIG 190 - 240 High pressure cut out / cut in, PSIG 500 / 390 Compressor Amps, beg . - end, freeze 5 .8 - 5 .0 Compressor Amps, harvest 6 .8 Cycle Time (minutes) Ambient Air Temp (deg . F) Water Temp 70 80 90 50 13 13-14 17 70 13-14 14 17-18 80 14-15 15 19-20 90 15-16 17 21-22 Low Side PressuresTechnical. Guidelines. Available in the following sizes. R-410A 25LB. CYLINDER 100 LB. CYLINDER 850LB. CYLINDER 1450 LB. Pressure-Temp Chart. R-410A. (R-32/125) (50 …

Find out about high-blood pressure during pregnancy. Some women with high-blood pressure develop preeclampsia. Learn how to avoid complications. Blood pressure is the force of your...This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron. Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157 Both are HFC refrigerants. They have zero ozone depletion potential. Major differences are: R32 is a single component refrigerant while R410A is a zeotropic blend. R32 has a lower boiling point (-52.5 0 C) than R410A (-48.5 0 C) R32 has a global warming potential of 675 while R410A has a GWP of 2088. R410A will no longer be in use after 2025 ...For the normal running pressure in an R134A system, the coil should run at 22 pounds per square inch at the lowest temperature, 45−20 = 25 degrees Fahrenheit. Similarly, at the highest temperature, 60−20 = 40 degrees Fahrenheit, the coil should run at 57 psi. In other words, the normal running pressure of R134A is between 22 and 57 psi in ...Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157Find out what causes high suction pressures and the consequences of high suction pressure. We examine the refrigeration cycle and work to solve the root of high suction pressure 410a problems. ... (For more information check Danfoss 067L5955, 1.5 - 3 TON TXV R410A) Table 1: R134a Saturation Properties pressure table (Reference: www.chemours.com ...Using the temperature rise method (CFM = KW (Volts X Amps) X 3.413 divided by (Temp rise X 1.08)), check the airflow. Using the manufacturer's coil specification sheets, confirm the pressure drop across coils. The airflow measurement is used to find the evaporator load, so it must be accurate. Check the system operating pressures.

Pressure Range Low side: 36 to 50 psi High side: 284 to 356 psi Indications Both pressures are TOO HIGH The low-side piping is not cold Causes Air in the system Remedy Evacuate the system Replenish the refrigerant Check the gauge readings If prolonged operation with air in the system, the liquid tank must be replaced.

November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ...Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. …Here are the five main differences between R32 and R410A refrigerant gases: 1. Boiling Point. R32 has a boiling point of -51 degrees Celsius, while R410a has a boiling point of -48.5 degrees Celsius. This means that R32 is less likely to cause condensation on surfaces, while R410a is more likely to cause condensation.1. The only accurate method of charging is to; A. charge until the sight glass is clear B. charge until gauge pressures are correct C. weigh the refrigerant into the system D. charge as a vapor with the engine running 2. Which of the following refrigerant has the lowest GWP? A. R410A B. R134A C. R152a D. R744R410a unit heat pump. Get to call and unit wont turn on. Customer stats unit runs for five minutes with hot air coming out the starts blowing cold. Check all switches and limits. Find the lower pressure switch open. Jump it go see if unit runs and see what the charge looks like. Unit is running 300/80 in heat mode.In fact, R-32 is used in quite a bit of blends in today's world. It is used to create various refrigerants such as: R-410A, R-407A, R-407B, R-407C, R-407D, R-407E, R-407F and R-410B. R-32 along with R-125 are some of the most versatile refrigerants used today. While we are used to using R-32 as a blend it is also seeing a rise of usage in ...If the system is very large, it is possible that 540g is not enough to bring the system pressure up to 11.54bar to correspond with the stated 15C ambient. May be worth checking the pressure in your R410A cylinder incase it is low also, maybe wrong refrigerant, 6.5bar would be correct for R407C for example.However, based on the gas laws you can approximately calculate your difference in saturation pressures. R410a runs between 60% and 70% higher saturation pressure. With a 10% concentration you will have approximately 6-7% higher saturation pressure than normal R22 alone. As it stands, here's what I would do if I made this mistake.The pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used.What are normal operating pressures for R134a? The normal running pressure of R134A is between 22 and 57 psi. What is the pressure of AC gas? If using AC refrigerant R-22, a 1.5 ton AC should ideally have the pressure between 65 and 70 PSI. For 1 ton AC, the AC gas pressure will be 60 to 65 PSI. What should 410A pressure be at 90 degrees? R ...

Does joe namath wear a toupee.

Greenstem provisioning.

What are normal operating pressures for R134a? The normal running pressure of R134A is between 22 and 57 psi. What is the pressure of AC gas? If using AC refrigerant R-22, a 1.5 ton AC should ideally have the pressure between 65 and 70 PSI. For 1 ton AC, the AC gas pressure will be 60 to 65 PSI. What should 410A pressure be at 90 degrees? R ...R-22 has been the most widely used refrigerant for many years but was phased out in 2020 due to its ozone depletion potential. Meanwhile, R-410A is an alternative that provides better performance and efficiency than its predecessor while not degrading the ozone layer. The primary difference between them is their compositions; specifically, R-22 ...What Will Replace R-410A? R-32 and R-454B refrigerants are slated to begin replacing R410A in U.S. HVAC equipment starting 2023. Here's what you need to know about R-32 and R-454B: R-32. Zero Ozone Depletion 1/3 GWP of HFC 410A Superior energy efficiency High refrigeration capacity & thermal conductivity Low pressure dropR-410A's higher operating pressures (60-70 percent higher than R-22) mean that contractors and techs are now using gauges designed for 410A. Refrigerant recovery equipment also must be designed for this refrigerant's pressures. R-410A will also produce refrigerant burns more quickly than R-22. Protective equipment is a vital part of safe work ...Constants for vapor pressure of saturated vapor (dew point), p g: A = -1.440004 E+00 E = -3.521484 E+00 B = -6.865265 E+00 F = -7.750000 E+00 C = -5.354309 E-01 X o = 2.086902 E-01 D = -3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ...Argument #1: Pressure. Tube-side materials in R-410A coils need to be thicker due to the higher operating pressures associated with R-410A relative to R-22. We’re not arguing that there’s not a difference in operating pressure between the two. There is – roughly 130 PSI for R-410A evaporators compared to about 70 for R-22.pressures and refrigeration capacity than R-22. The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of theR-410A Considerations: The IPR will open at a pressure 550 - 625 psig for R-410A systems. The high pressure switch opens at 610 psig ±. 10 psi g and cl oses at 500 psi g ± 15 psi g. The low pressure control will open at 50 psig. The discharge temperature of R-410A is lower than R-22 due to its higher vapor heat capacity.Under (Atmospheric) Pressure - The pressure of the atmosphere is immense, and it grows as you get closer to the planet's surface. Learn about pressure and how it affects weather. A...Minimum order 250. 2. Bulk Pack Only. 50 per box. Minimum order 100. 3. R-410A compatibility offered with P266SNR-2C transducer. PRODUCT SWITCH ACTION BOTTOM OF RANGE TOP OF RANGE MAXIMUM WORKING PRESSURE TYPICAL APPLICATIONS. P70 SERIES ADJUSTABLE ON/OFF PRESSURE CONTROLS. P70AA-2CSPST Open Low 0 150 325 Suction pressure control — loss of ...As we will see in the R-22 and R-410A examples at the end, target superheat for a system using R-22 and the target superheat for a system using R-410A (or any other refrigerant) are the same. Only the DB and WB temperatures determine the target superheat. Here is the formula we use to calculate superheat: Target Superheat = (3 × TWet Bulb ... ….

The high-side saturation pressure is 365 psig and the unit's technical manual specifies 10°F of liquid subcooling. What would the desired liquid-line temperature be at the outlet of the condensing unit? 100°F. A technician is working on an R-404A refrigeration system and determines that the head pressure is 205 psig and the condenser outlet ...In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur...What is an R410A PT Chart? An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems.R454B vs R410A: Cost Comparison. Let's talk money. Because let's face it, cost is a big factor in any decision. Purchase Price. R410A is typically cheaper to buy initially, but remember - cheaper isn't always better in the long run. Maintenance and Operation Costs. While R410A may be cheaper upfront, R454B could save you money over time.R32 is a single compound, while R410A is made from a mixture of R32 and R125. R410A has high pressure making it difficult to handle. R32 has higher cooling efficiency. In AC gas refilling, less R32 is required than R410A. R32 is moderately more flammable than R410A. What are the Advantages of Switching to R32. More efficient.1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor …Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. …The perfect refrigerant reading depends on several factors, like atmospheric pressure and temperature. I like to see an average range of 58-85 PSI on the low side and 120-300 PSI on the high side. These indicate that the unit is running okay and should be cooling properly. TL;DR: R22 is almost phased out and even banned. Running pressures for 410a, This manual is also suitable for: View and Download Daikin R-410A technical data manual online. Outdoor units. R-410A air conditioner pdf manual download. Also for: Rxs-g2v1b., For example, the IPR will open at a pressure of 375 to 450 psig for R-22 systems and a pressure of 550 to 625 psig for R-410A systems. Kramer noted that the suction and discharge pressures are 50 percent to 70 percent greater with R-410A than R-22, but the discharge temperature of R-410A is lower due to its higher vapor heat capacity., Practical Applications of the Subcooling Chart 410a. System Troubleshooting and Diagnostics. Identifying Overcharge or Undercharge Issues. Detecting Refrigerant Leaks. Assessing System Efficiency. System Maintenance and Optimization. Adjusting Refrigerant Charge. Evaluating Expansion Valve Performance. Balancing System Capacity., Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C). , In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the..., pressure of about 250 psi at an outdoor temperature of 95°F. With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page. (Note that in most cases, equipment designed for R-22 cannot use R-410A because of this difference in operating, FAQs about refrigerant pressures & charge quantity for air conditioners & heat pumps. This air conditioning repair article series discusses the the diagnosis and correction of abnormal air conditioner refrigerant line pressures as a means for evaluating the condition of the air conditioner compressor motor, which in turn, is a step in how we evaluate and correct lost or reduced air conditioner ..., R32 has a GWP of 675, approximately 70% lower than the GWP of R410A, which is 2088. Due to its single-component nature, R32 heat pumps use 20% less refrigerant than R410A heat pumps. Consequently, their operational costs are lower. R410A refrigerant cannot be reclaimed like R32, as the former is a blend., Anon The compressor is running and producing no pressure it's possible that it's because you've lost the refrigerant charge from the system. On 2020-06-14 - by (mod) - ... I have a 3 ton 410a Lennox with correct suction pressure however my high side pressure is way low. Pressures are 120headover 118 suction low side. What would be the cause., Below we list a dozen causes of high head pressure in an air conditioner or heat pump compressor motor. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Air contamination in the refrigerant system. Air flow blocked across the condensing coil. Low condenser airflow will show up as high head pressure, normal ..., What is an R410A PT Chart? An R-410A Pressure-Temperature (PT) chart is a tool used in HVAC systems to determine the corresponding saturation temperature of the R-410A refrigerant at different pressures. This chart is essential for HVAC technicians as it helps in diagnosing and maintaining air conditioning systems., As an HVAC technician or someone interested in air conditioning systems, understanding the key factors that impact 410A refrigerant pressures is crucial. The proper functioning of ..., Aug 5, 2023 · Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so. , Saturation Pressure-Temperature Data for R-410A (psig)*. Temp. Temp. Temp. Temp. Temp. Temp. Temp. Temp. ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) ( F) Liquid Vapor ( C) -49 5.5 5.4 -45.0 1 49.7 49.5 -17.2 51 145.8 145.2 10.6 101 323.1 322.1 38.3 -48 6.0 5.9 -44.4 2 51.1 50.8 -16.7 52 148.4 147.9 11.1 102 327.7 326.7 ..., The technician installs pressure gauges to obtain the system pressures. New air-conditioning systems use R-410A. If the system were standing at 80°F, the system should have 235 psig of pressure, according to the temperature/ pressure chart for R-410A at 80°F. NOTE: Care should be used in the standing pressure comparison., Step 2. Connect the yellow hose on the manifold gauge to the 410A refrigerant tank. Turn the handle on top of the tank to release refrigerant from the tank. Flip the tank upside down so that it will charge the system in a liquid state., What are the pressure differences between R410A, R32, and R454B? R410A, 434 psigR454B, 405 psigR32, 444 psig#hvac #hvactechnician #hvacfamily #hvactech #hvac..., R410A is a blend of two hydrofluorocarbon (HFC) refrigerants: R32 and R125. These two components work together to create a refrigerant with excellent thermodynamic properties. R32 provides high energy efficiency, while R125 contributes to the stability and heat transfer performance of R410A. When it comes to the chemical composition of R410A ..., The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. , Air conditioner suction pressure too high pipe not cold what's Problem how repair Learn tips Tricks very useful information new technician much open this wat..., R-410A air conditioner and heat pump split system matches of nominal capacity 90,000 and 120,000 Btuh. This guideline ... Proper adjustment means pressure and temperature of the liquid line at the indoor unit must be measured to calculate subcooling at the indoor unit. If subcooling at the, Oct 9, 2019 · What is the standing and discharge pressure of a refrigerant? Refrigerant pressure readings R-22, R-410A, R-290, R-417A 1 Standing pressure – 150 PSI 2 Saction pressure – 60 TO 70 PSI 3 Discharge pressure – 250 TO 300. Freon gas standing and working pressure ( R32, R410A, R502,R407C, R134A etc ) , at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a "Rose" color to indicate the type of refrigerant and may contain a "dip" tube to allow for charging of liquid refrigerant into the sys-tem. All R-410A systems use a POE oil that readily absorbs moisture from the ..., I've seen lower seer units running the liquid line hot while higher seer units it's barely above ambient, so little you almost can't tell by hand. Single pipe quasi-vapor system. Typical operating pressure 0.14 - 0.43 oz. EcoSteam ES-20 Advanced Control for Residential Steam boilers., Pressure/temperature relationship. I was discussing some pressures with another tech. He asked me about an r410a unit that the pressures were 125 psig= 43 degrees back pressure over 350psig =107 degrees condensing pressure he says oh that's all out of whack and 350 is to high because when I do my maintenances I usually see 150/275 300 max., With 75 indoor you should be running approximately 190 on the low side. The correct way to charge the unit would have been to weigh the charge in and in the cooling mode. So if you have 190 suction I would leave it as is and return when it is warm (70) outside to adjust the charge. Bart Jay. 655 Satisfied Customers., The port sizes for R410A and R22 TXV's are basically identical, so they would each have the same flow capacity with either refrigerant . The difference is a R410A TXV will work properly with R22 only if you change out the R401A powerhead to one for R22. It'll then actually control superheat. The Educational Forums., The low side is running about 165 and the high side is 365. The low side was high like this before I change out the coil. I that case the charge was low, but I would of expected a lower pressure on the low side. IT about 97 out side right now. ... (22 mos. old# the inside coil continues to freeze up installer pulled pressure #410a) ..., R32 has a GWP of 675, approximately 70% lower than the GWP of R410A, which is 2088. Due to its single-component nature, R32 heat pumps use 20% less refrigerant than R410A heat pumps. Consequently, their operational costs are lower. R410A refrigerant cannot be reclaimed like R32, as the former is a blend., The unit was charged in heating mode and 11lbs 1 oz of refrigerant was used. When the heat pump is running it blows semi-warm air like it is operating correctly but when I put my gauges on the system the high side pressure was 425 and low side was 395-400., The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ..., ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ..., Moreover, the operating, running pressures are closer to 165 PSI at the coil. Contamination Based on a 9 year history of this practice and 2 dozen plus warehouse test mutts, we know conclusively that there is no more risk of cross-contamination from R22 to the new 410a with a condenser only change out than if you were changing the evap coil too.